- Add `rem_local: bool` to UnitRuntime; set true when any equipment's
REM signal is false with good quality
- Engine check_fault_comm: stop auto-control and fire AutoControlStopped
when any equipment switches to local mode
- Block start-auto when rem_local (backend + error message)
- Frontend: disable Start Auto button in units/ops views when rem_local
- Frontend: disable equipment Start/Stop buttons in config view when
unit's rem_local is true
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Signal indicators are now wider pill badges (40×20px rect) with the role
label (REM/RUN/FLT) embedded inside, replacing the 10px dot+label rows.
Equipment Start/Stop buttons are disabled when:
- auto control is active
- REM = 0 (device in local mode, not accepting remote commands)
- FLT = 1 (fault active)
Button state reacts in real time to WS signal updates via a per-equipment
syncBtns closure registered in state.opsUnitSyncFns.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Prevent starting unit auto control while fault_locked or manual_ack_required,
enforcing that faults must be manually acknowledged before resuming automation.
Also disable the Start Auto button in the frontend with descriptive tooltips.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Ops view now reads equipment+role_points from state.units (returned by
unit list API) instead of state.equipments, eliminating the loadEquipments()
call on bootstrap.
Config data (sources, equipments, events, points) is deferred until the
user first switches to config view. On WS reconnect, loadEquipments is
only refreshed when config view is active.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Equipment list response now includes signal-role points with monitor data,
so the ops view can render signal dots directly from state.equipments
without fetching /api/unit/:id/detail.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
startOps() was calling loadAllEquipmentCards() redundantly — the
units-loaded event listener already calls it after loadUnits()
completes. This caused two parallel requests to /api/unit/:id/detail
for every unit on page load.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- ops.js: remove unused `formatValue` import
- logs.js: remove `export` from internal-only `appendLog`
- state.js: fix stale comment ({ valueEl, qualityEl } → { dotEl })
- docs: rewrite both plan docs in Chinese; update dual-view-web plan to
reflect actual implementation (sigDotClass dots, loadAllEquipmentCards,
syncEquipmentButtonsForUnit, batch auto buttons in startOps)
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Engine now spawns one async task per enabled unit (supervised every 10s)
- wait_phase uses sleep_until + select! for precise timing; 500ms fault-tick
runs inside each phase so fault/comm is still checked promptly
- WS UnitRuntimeChanged pushed only on state transitions, not every tick
- ControlRuntimeStore gains notify_unit/get_or_create_notify for instant
wake-up when handlers change auto_enabled or fault_locked
- UnitRuntime: remove last_tick_at, current_run/stop/distributor_elapsed_sec;
add display_acc_sec (snapshot at transition, avoids mid-cycle jitter)
- accumulated_run_sec now increments by exact run_time_sec*1000 per cycle
- unit.state_changed events no longer written to DB (too frequent)
- Frontend: show display_acc_sec instead of accumulated_run_sec
- styles: event-card flex-shrink:0 fixes text overlap under flex column
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Backend:
- POST /api/control/unit/batch-start-auto — starts auto on all enabled
units that are not fault/comm locked and not already running auto
- POST /api/control/unit/batch-stop-auto — stops auto on all units
Frontend (ops view):
- Add "全部启动" / "全部停止" buttons in the unit sidebar header
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- validator: reject equipment start/stop when unit auto_enabled
- engine: fix stop_time_sec==0 causing infinite Stopped state (never starts)
- engine: call simulate_run_feedback after auto commands when SIMULATE_PLC=true
- command: extract simulate_run_feedback to shared module (was private in handler)
- web: disable Start/Stop buttons when unit auto is active; sync on WS runtime update
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Add 运维/配置 tab switch; grid-ops / grid-config layout classes
- New ops-panel: unit sidebar + equipment card grid (REM/RUN/FLT signals)
- All equipment cards shown by default; unit click acts as filter
- Signal cells seed from point_monitor cache on render, then update via WS PointNewValue
- New log-stream-panel: SSE realtime log stream, active only in config view
- Backend: get_unit_detail now includes point_monitor (current value) in each point
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>